Setting alarm parameters – HP StorageWorks Enterprise File Services WAN Accelerator User Manual

Page 116

Advertising
background image

116

C

ONFIGURING

THE

HP EFS WAN A

CCELERATOR

Setting Alarm
Parameters

You can set alarms in Reports - Alarm Settings page.

Enabling alarms is optional.

To set alarm
parameters

1. Click the Setup tab to display the Setup menu.

2. Click Reports to display the Reports - Alarm Settings page.

Figure 2-47. Reports - Alarm Settings Page

3. Use the controls to complete the configuration, as described in the following table.

Control

Description

CPU Alarms

Raise Alarm When CPU Utilization Reaches. Specify this option to trigger an alarm if
the average and peak threshold for the Central Processing Unit (CPU) utilization is
exceeded. When an alarm reaches the rising threshold, it is activated; when it reaches the
lowest or reset threshold, it is reset. After an alarm is triggered, it is not triggered again
until it has fallen below the reset threshold.

This alarm is enabled by default, with a rising threshold of 90% and a reset threshold of
70%.

Rising Threshold. Specify rising value CPU utilization.

Reset Threshold. Specify reset value for CPU utilization.

Data Store Alarm

Send email if stale data replaced by fresh data is less than __ day(s) old. Specify this
option to trigger an alarm if data in the data store is replaced with new data before the
time period specified.

Advertising