Error codes – HP StoreEver MSL Tape Libraries User Manual

Page 49

Advertising
background image

NOTE:

See the

HP StorageWorks MSL2024, MSL4048, and MSL8096 Tape Libraries user and service guide

for additional Library error codes.

Table 5 Error codes

Solution

Cause

Message

Code

If this is a new installation,
verify that the Extender is
installed properly and that
both Libraries are powered
on.

Power cycle both Libraries.

See

Table 6

, page 50 for de-

tails.

Library Extender missing.

B8

If this is a new installation,
verify that the Extender is
installed properly and that
both Libraries are powered
on.

Power cycle both Libraries.

See

Table 7

, page 50 for de-

tails.

Communication error on the
I²C bus between the master
Library and the Extender.

B9

If this is a new installation,
verify that the Extender is
installed properly and that
both Libraries are powered
on.

Power cycle both Libraries.

The master Library cannot
communicate with the lower
Library.

Communication error on the
serial connection between the
master and lower Libraries.

BA

If this is a new installation,
verify that the Extender is
installed properly and that
both Libraries are powered
on.

Power cycle both Libraries.

The master Library has some
communication with the lower
Library, but not enough to
function.

Stack link not established due
to communication issues
between the master and lower
Libraries.

BB

Verify that the lower Lib-
rary is powered on.

Verify that extended mode
is enabled in the lower
Library.

Power cycle both Libraries.

If the lower Library is an
MSL4048, verify that its
power supply status is
Good

.

Verify that the master and
lower Libraries have the
most recent firmware ver-
sions.

The lower Library did not re-
spond to the master Library
within the specified time.

Power of lower Library not de-
tected in time.

BC

HP StorageWorks MSL Library Extender user guide

49