HP StoreEver MSL Tape Libraries User Manual

Page 51

Advertising
background image

Solution

Cause

Message

Sub-code

Power cycle the master
Library and run the Library
Extender cycle test.

Retry the operation. If the
motor is still blocked, re-
move the Extender from the
Libraries, and then inspect
the Extender and master
Library for a physical
blockage. Re-install the Ex-
tender.

The Extender robotic is stuck
in its home position within the
master Library.

Motor blocked in master home
position.

03

Power cycle the lower Lib-
rary and run the Library
Extender cycle test.

Retry the operation. If the
motor is still blocked, re-
move the Extender from the
Libraries, and then inspect
the Extender and lower
Library for a physical
blockage. Re-install the Ex-
tender.

Retry the operation.

The Extender robotic is stuck
in its home position within the
lower Library.

Motor blocked in lower home
position.

04

Power cycle both Libraries
and run the Library Ex-
tender cycle test.

Retry the operation. If the
motor is still blocked, re-
move the Extender from the
Libraries, and inspect the
Extender and master Lib-
rary for a physical block-
age. Re-install the Extender.

Retry the operation.

The Extender robotic is stuck
between its two home posi-
tions.

Motor blocked between master
and lower home position.

05

Power cycle the both Librar-
ies and run the Library Ex-
tender cycle test.

Retry the operation. If the
motor is still blocked, re-
move the Extender from the
Libraries, and then inspect
the Extender and master
Library for a physical
blockage. Re-install the Ex-
tender.

The Extender robotic is stuck
and the motor is hot.

Motor blocked and hot.

06

HP StorageWorks MSL Library Extender user guide