Listing supported tests (clf) – HP StoreEver TapeAssure Software User Manual

Page 90

Advertising
background image

This file is overwritten each time a scan is performed. The output is written in
the following format:

<device path>:<vendor ID>:<product ID>:<firmware version>

The device path varies depending on the operating system. The device path is
specified with the p= parameter when running a ticket, test, or firmware upload.

The password and iohistory parameters are optional. I/O mode cannot
be set while doing the scan; it must be set before performing the scan.

Syntax

hp_ltt -f scan [iohistory=enable|disable]

[instname=<instance name>] [dirpath=<directory path>]

Parameters

Optional. Specify enabled or disabled. When enabled,
L&TT generates a detailed event log that captures all L&TT

iohistory

diagnostic interaction, all SCSI commands sent and received
by the program, and any software interactions or issues. If an
invalid value is provided, L&TT retains the existing setting.

instname

Specify a name for this instance of L&TT. This parameter is
optional for the first instance of L&TT and required for all other
instances of L&TT. If this parameter is supplied, the log files from
this instance will be created in a logs_<instance name>
folder in the logs folder of the L&TT installation directory or
directory specified by dirpath.

dirpath

Specify the absolute path for the temporary directory used by
L&TT for its runtime files. This parameter is optional when L&TT
is run from the system installation directory and required when
L&TT is run from removable media, such as a USB flash drive
or CD.

When running L&TT from the system installation directory, if
dirpath

is specified and instname is not specified, the L&TT

runtime files will be created in the dirpath directory. Otherwise,
if dirpath is specified, the L&TT runtime files will be created in
<dirpath>/logs_<instance name>

.

Example

hp_ltt -f scan

This command produces the following output in a file named saved_scan.txt
in the current folder:

2/0.4.0:HP:Ultrium 3-SCSI:G54D

From this output, the device hardware path is:

2/0.4.0

For each device L&TT finds during the scan there will be a corresponding entry
in this file.

Listing supported tests (CLF)

Description

Run this command to see a list of tests supported for a device. The list is
displayed on the terminal.

Syntax

hp_ltt -f listtest p=<device path>

Parameters

Enter the device path. The format for the device path is specific to the
operating system. To determine the format for your operating system and

p

device, scan the bus. (See

Scanning the bus (page 89)

). The output of the

scan is written to the saved_scan.txt file in the L&TT root directory. The output
is in the proper format for use in this command. This parameter is required.

90

Command line functionality

Advertising