En.06 unrecoverable condition-no blowers installed – HP 3000 Enterprise Virtual Array User Manual
Page 171

EMU Generated Condition Reports
171
Enterprise Virtual Array 3000 User Guide
0.3.en.06 UNRECOVERABLE Condition
—
No Blowers Installed
Note:
When this condition exists there will be two error messages.
The first message will be
0.3.en.05
and will identify the first blower.
The second message will be
0.3.en.06
and will identify the second blower.
The EMU cannot detect any installed blowers. Shutdown is imminent! The EMU
will shut down the enclosure in 7 minutes unless you correct the problem. This
condition report remains active until you correct the problem or the EMU shuts
down the power supplies, whichever occurs first.
Complete the following procedure to correct this problem.
1. Record all six characters of the condition report.
2. Use the controller shutdown procedure to shut down the controllers.
3. Contact your HP authorized service representative.