Drive status displays – HP 3000 Enterprise Virtual Array User Manual
Page 84

Storage System Hardware Components
84
Enterprise Virtual Array 3000 User Guide
Drive Status Displays
When displaying status, the LEDs are either On, Off, or Flashing. In some
configurations, the host controller can control the status LEDs. The operational
drive LED status displays are shown in
for the
nonoperational drive status LED displays.
Note:
The drive is configured as part of an array. DO NOT replace an active drive.
Table 13: Operational Drive Status Displays
Drive Ready
Drive On-line
Drive Failure
Description
Flashing
(medium speed)
On
Off
Initial startup.
On
On
Off
The operational drive is not being
accessed.
Flashing
(high speed)
Flashing
(medium speed)
On
The drive is being located.
Flashing
On
Off
The drive is operational and active.
Table 14: Nonoperational Drive Status Displays
Drive Ready
Drive On-line
Drive Failure
Description
On
On
On
Indicates no connection or the controllers
are offline. Recommended corrective
actions:
1. Check power supplies for proper
operation.
2. If defective, replace drive.
On
Off
Flashing
Indicates drive error/not active.
Recommended corrective actions:
1. Verify drive loop continuity.
2. Replace drive.