Host conditions, F.f.en.01 information condition-host generated – HP 3000 Enterprise Virtual Array User Manual
Page 187

EMU Generated Condition Reports
187
Enterprise Virtual Array 3000 User Guide
8.7.en.12 NONCRITICAL Condition
—
I/O Module NVRAM Read Failure
The system is unable to read data from the I/O module NVRAM.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Contact your HP authorized service representative.
Host Conditions
The EMU has the capability of displaying host controller defined condition
reports on the EMU alphanumeric display.
The format of a host condition report is F.F.en.ec, where:
■
F.F. is the host element type number
■
en. is the two-character host element number
■
ec is the error code
The host controller can display host controller defined error codes on the EMU
alphanumeric display
F.F.en.01 INFORMATION Condition
—
Host Generated
The host controller (HSV) defines the error type and the affected elements. These
messages may be displays on the Command View EVA GUI. The proper
corrective action depends on the element and error.