HP StorageWorks XP Remote Web Console Software User Manual

Page 64

Advertising
background image

yyyy/mm/dd hh:min Source candidate = LDKC:CU:LDEV in Group X-X
(a) (b) (c)
Failed to specify a proper target volume for this source candidate.
Cause: XXXXXXXXXXXX
(d)

XP Auto LUN could not find a proper candidate for the target volume corresponding to the specified
candidate for the source volume.

(a) Start time of creating this auto migration plan

(b) Candidate for the source volume

(c) Parity group of the candidate for the source volume

(d) Reason why a proper target volume could not be found:

The parity group to which the candidate for the
target volume belongs includes a volume that was
migrated in the specified sampling term.

The parity group of the target candidate includes
a volume that was migrated in the specified
sampling term.

If XP Auto LUN migrates the candidate for the
source volume, the disk usage rate of the parity
group to which the source volume will be migrated
might exceed the HDD class threshold. Check the
values of the HDD class thresholds in the Attribute
window, and change the value, if required.

The disk usage rate of the parity group might
exceed the class threshold.

There are insufficient reserved volumes. Check the
number of reserved volumes and their locations.

Insufficient reserved volumes.

E. Other messages

yyyy/mm/dd hh:min The parameters for creating auto migration plans were
initialized.
(a)

The parameters for creating auto migration plans were initialized.

(a) Time when the parameters were initialized

yyyy/mm/dd hh:min Failed to initialize the parameters for creating auto
migration plans.
(a)

XP Auto LUN failed to initialize the parameters for creating auto migration plans.

(a) Time when the initialization failed

yyyy/mm/dd hh:min The auto migration plan(s) ere deleted.
(a)

The auto migration plans were deleted.

(a) Time of deletion

yyyy/mm/dd hh:min Auto migration is not available. All the parity groups
cannot be used for
(a)
auto migration.

All the parity groups in the storage system cannot be used as the auto-migration source or target. Auto
migration of volumes is not available. This message is output when you start XP Auto LUN in the following
conditions:

All volumes in the storage system are external volumes.

All parity groups in the storage system have On-Demand settings.

(a) Output time of this message

An internal logic error occurred.

An internal logic error occurred in the SVP. For the measures, call HP technical support.

64

XP Auto LUN Operations

Advertising
This manual is related to the following products: