HP StorageWorks XP Remote Web Console Software User Manual

Page 73

Advertising
background image

Table 17 Errors during Volume Migration or Migration Cancellation by using RAID Manager

(continued)

Measure

Cause

Error Code

(SSB2)

Error Code

(SSB1)

2322

Release the pair of XP Business Copy,
and then migrate the volume.

The migration source volume is set as the
leaf volume of XP Business Copy.

Release the pair of XP Business Copy,
and then migrate the volume.

The migration target volume is set as the
secondary volume of XP Business Copy.

2328

Release the volume from XP Auto LUN,
and then perform the volume migration.

The migration source volume is already
specified as the target volume of XP Auto
LUN.

232F

Do the following measures respectively:

1.

Cancel the reservation by XP Auto
LUN, and then perform the volume
migration.

2.

This volume migration cannot be
executed. Check the configuration
definition file.

Either of the following causes can be
considered:

1.

The migration source volume is
already reserved by XP Auto LUN.

2.

The number of slots does not match
between the migration target volume
and the migration source volume.

2331

Reduce the number of pair settings for
the specified volume, and then perform
the volume migration.

You cannot add any more pair settings
to the volume specified as the migration
source.

2332

It is trying to perform the migration
cancellation of the pair that is not
migrating. Check the configuration
definition file.

The volume specified by the migration
cancellation is not a migration source
volume

2333

This volume migration cannot be
executed. Check the configuration
definition file.

The emulation type does not match
between the migration target volume and
the migration source volume.

2336

Release the XP Business Copy pair, and
then perform the volume migration.

The migration source volume is a leaf
volume of XP Business Copy.

2337

Release the XP Business Copy pair, and
then perform the volume migration.

The migration target volume is a primary
volume of XP Business Copy.

233B

Release the XP Business Copy pair, and
then perform the volume migration.

The migration target volume is a
secondary volume of XP Business Copy.

233C

Release the volume from XP Auto LUN,
and then perform the volume migration.

The migration target volume is already
specified as the target volume of XP Auto
LUN.

2342

Release the pair of XP Business Copy,
and then migrate the volume.

The migration target volume is set as the
primary volume of XP Business Copy.

2343

It is trying to perform the migration
cancellation of the pair that is not
migrating. Check the configuration
definition file.

The volume specified by the migration
cancellation is not a migration target
volume.

2344

Release the XP Continuous Access pair,
and then perform the volume migration.

The migration target volume is a primary
volume of XP Continuous Access.

2346

Release the XP Continuous Access pair,
and then perform the volume migration.

The migration target volume is a
secondary volume of XP Continuous
Access.

2347

Release the volume from XP Auto LUN,
and then perform the volume migration.

The migration target volume is already
specified as the source volume of XP Auto
LUN.

234B

2350

Troubleshooting When Using RAID Manager

73

Advertising
This manual is related to the following products: