Table 21 tso command parameters, 21 tso command parameters, Table 21 – HP StorageWorks XP Remote Web Console Software User Manual

Page 69

Advertising
background image

ShadowImage for z/OS user guide

69

Quick Resync Pair

CESTPAIR

PPRCOPY ESTPAIR Resynchronizes a pair,

starts quick resync.

The specified volume
must be

split

,

V-split

or

suspended

Reverse Resync Pair

CESTPAIR

PPRCOPY ESTPAIR Resynchronizes a pair,

starts reverse resync.

The specified volume
must be

split.

Quick Restore Pair

CESTPAIR

PPRCOPY ESTPAIR Resynchronizes a pair,

starts quick restore.

The specified volume
must be

split.

Delete Pair

CDELPAIR

PPRCOPY DELPAIR Deletes a pair, changes

status to simplex.

The specified volume
must be other than

simplex

.

Suspend Pair

Not available

1

Not available

1

Stops update copy

operations.

The specified volume
must be other than

simplex

.

Detail (the Detail

window),

the History window.

CQUERY

PPRCOPY QUERY

Displays detailed pair

status information.

None.

1. The SI390 suspend operations cannot be requested using PPRC commands. The CSUSPEND/PPRCOPY SUSPEND commands

execute split operations on SI390 pairs.

Table 21

TSO command parameters

Command

Parameter

Description

CESTPAIR

DEVN

Device number.

PRIM

Primary volume (S-VOL): SSID, serial number, channel connection address, CU

number (only for the DKC emulation type 2105).
You can set an additional parameter corresponding to each request instead of a

serial number.

(1) For an Add and Split request (refer to

Adding and Splitting Pairs

” on

page 56), the parameter is MSF00. This request is valid for MODE(COPY) only.

The parameter locations and descriptions are as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘S’ = Split Å Requests simultaneous add and split.
Byte 9: Subcode-2. ‘F’ = Fast Mode Å Requests quick split.
Byte 10-11: Not used (xF0*2)

(2) For a Quick Resync request, the parameter is MRF00. This request is valid for

MODE(RESYNC) only. The parameter locations and descriptions are as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘R’ = Resync Å Distinguishes resync from add.
Byte 9: Subcode-2. ‘F’ = Fast Mode Å Requests quick resync.
Byte 10-11: Not used (xF0*2)

Table 20

PPRC commands (continued)

SI390

Command View

XP or XP Remote

Web Console

Operation

TSO

Command

ICKDSF

Command

Function

Restrictions