Table 22 ickdsf command parameters, 22 ickdsf command parameters, Table 22 – HP StorageWorks XP Remote Web Console Software User Manual

Page 72

Advertising
background image

72

ShadowImage for the XP128/XP1024/XP10000/XP12000

Table 22

ICKDSF command parameters

Command

Parameter

Description

ESTPAIR

DDNAME |

SYSNAME |

UNITADDRESS

DDNAME = dname = JCL statement identifying the volume.
SYSNAME = sysxxx = SYSNAME in the ASSGN system control statement.
UNITADDRESS = ccuu = device number.

PRI

Primary volume (S-VOL): SSID, serial number, channel connection address.
You can set an additional parameter corresponding to each request instead

of a serial number.

(1) For an Add and Split request (refer to

Adding and Splitting Pairs

” on

page 56), the parameter is MSF00. This request is valid for MODE(COPY)

only. The parameter locations and descriptions are as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘S’ = Split Å Requests simultaneous add and split.
Byte 9: Subcode-2. ‘F’ = Fast Mode Å Requests quick split.
Byte 10-11: Not used (xF0*2)

(2) For a Quick Resync request, the parameter is MRF00. This request is valid

for MODE(RESYNC) only. The parameter locations and descriptions are as

follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘R’ = Resync Å Distinguishes resync from add.
Byte 9: Subcode-2. ‘F’ = Fast Mode Å Requests quick resync.
Byte 10-11: Not used (xF0*2)

(3) For a Quick Restore request, the parameter is MRQ00. This request is

valid for MODE(RESYNC) only. The parameter locations and descriptions are

as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘R’ = Resync Å Distinguishes resync from add.
Byte 9: Subcode-2. ‘Q’ = Quick Mode Å Requests quick restore.
Byte 10-11: Not used (xF0*2)

(4) For a Reverse Resync request, the parameter is

MRR00

. This request is

valid for MODE(RESYNC) only. The parameter locations and descriptions are
as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘R’ = Resync Å Distinguishes resync from add.
Byte 9: Subcode-2. ‘R’ = Reverse Resync Å Requests reverse resync.
Byte 10-11: Not used (xF0*2)
If you set a parameter other than the above parameters, the command will be

rejected.

SEC

Secondary volume (T-VOL): SSID, serial number, channel connection address.

Advertising