ShadowImage for z/OS user guide

71

ONLINSEC

YES = Does not check path group.
NO = Checks path group.
CU number or this parameter is valid only for the DKC emulation type 2105.
For MODE (COPY), the path group for the T-VOL is checked. For Quick Restore or

Reverse Resync request is made in MODE (RESYNC), the path group for both the

primary volume (S-VOL) and target volume (T-VOL) is checked.

CSUSPEND

DEVN

Device number.

PRIM

Primary volume (S-VOL): SSID, serial number, channel connection address, CU

number (only for the DKC emulation type 2105).
You can set an additional parameter corresponding to each request instead of a

serial number. For a steady split request, the parameter is MPS00. This request is

valid for steady split. The parameter locations and descriptions are as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘P’ = SPLIT
Byte 9: Subcode-2. ‘S’ = Steady Split Å Requests steady split.
Byte 10-11: Not used (xF0*2)
If you set a parameter other than the above parameters, the command will be

rejected.

SEC

Secondary volume (T-VOL): SSID, serial number, channel connection address, CU

number (only for the DKC emulation type 2105).

PRIMARY

Not applicable.

QUIESCE

For information on the QUIESCE parameter, see ”

CSUSPEND QUIESCE

Parameter

” on page 79.

The parameter is valid only for the DKC emulation type 3390.

CDELPAIR

DEVN

Device number.

PRIM

Primary volume (S-VOL): SSID, serial number, channel connection address, CU

number (only for the DKC emulation type 2105).
Among them, the following shows the additional parameters that can be set

according to the requests made in replacement of the serial number.
For an At-Time Split Delete request, the parameter is MAnn0. The parameter

locations and descriptions are as follows:
Byte 0-6: fixed value (xF0*7)
Byte 7: Indication of MRCF. 'M' = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. 'A' = At-Time Split Å Distinguishes at-time split from add.
Byte 9-10: Consistency group ID. 'nn' = Consistency group ID specified

hexadecimally Å Requests at-time split delete.
Byte 11: Not used (xF0)

SEC

Secondary volume (T-VOL): SSID, serial number, channel connection address, CU

number (only for the DKC emulation type 2105).

CQUERY

DEVN

Device number.

PATHS

Not applicable.

CRECOVER

CRECOVER is not used for SI390.

CGROUP

CGROUP is not used for SI390.

Table 21

TSO command parameters (continued)

Command

Parameter

Description

Advertising