Utl alarm cli commands, Ovl: overload alarm – HP e-Commerce Server Accelerator sa7120 User Manual

Page 126

Advertising
background image

C H A P T E R 7 HP e-Commerce Server Accelerator SA7100/SA7120 User Guide

116

UTL Alarm CLI commands

To set Utilization Threshold Alarm time window:

set utl_window <seconds> (Range: 5-65000,

default: 15)

To set Utilization Threshold Alarm high-water value:

set utl_highwater <percentage> (Range: 2-100,

default: 90)

To set Utilization Threshold Alarm low-water value:

set utl_lowwater

<percentage> (Range: 1-99,

default: 60)

To display current settings:

show utl_window

show utl_highwater

show utl_lowwater

Examples:

HP SA7120> set utl_window 10

HP SA7120> show utl_window

Utilization Window set [secs]: 10

HP SA7120> set utl_highwater 80

HP SA7120> show utl_highwater

Utilization High water mark [%]: 80

HP SA7120> set utl_lowwater 60

HP SA7120> show utl_lowwater

Utilization Low water mark [%]: 60

OVL: Overload
Alarm

WARNING: This alarm
indicates loss of encryp-
tion/decryption. (Normal
SSL operation resumes
when the alarm ceases.)

When enabled, an alarm is issued upon occurence of overloads
resulting in spills or throttles during the current user-configured
alarm period (5 to 65000 seconds, default: 15 seconds).

Format:

A:mm/dd/yyyy hh:mm:ss

OVL:SPIL|THRT:XXX:

/*message*/

Where:

A: identifies the message as an alarm.

mm/dd/yyyy hh:mm:ss is the timestamp.

OVL: identifies the message as an Overload

Alarm.

Advertising