Viewing system port alerts – HP 3PAR Operating System Software User Manual

Page 109

Advertising
background image

The lower pane provides the following information:

Description

Field

Group

Position of the port in which the SFP is installed.

Position

General

Current condition of the SFP.

State

Manufacturer of the SFP.

Manufacturer

Part number of the SFP.

Part Number

Serial number of the SFP.

Serial Number

SFP's revision level.

Revision

Maximum speed allowed by the SFP.

Max Speed

Displays whether the SFP has been tested and if the SFP is supported.

Qualified

Displays whether the transmit laser is disabled.

TX Disable

Displays whether the transmit laser has a problem.

TX Fault

Displays whether the receive end of the SFP is experiencing a loss
of signal from the host or drive cage.

RX Loss

Displays whether the SFP receive power is low.

RX Power Low

Displays whether the SFP is DDM-capable (Digital Diagnostic
Monitoring).

DDM Support

Identifies the monitored parameters (temperature, voltage, TX bias,
TX power, and RX power).

Type

DDM

The unit of measure used for the monitored parameters.

Unit

The current measured value.

Value

The manufacturer's recommended lower-limit warning level.

Low Threshold Warning

The manufacturer's recommended upper-limit warning level.

High Threshold Warning

The manufacturer's recommended lower-limit alarm level.

Low Alarm Threshold

The manufacturer's recommended upper-limit alarm level.

High Alarm Threshold

Viewing System Port Alerts

To view port alerts:
1.

Access the Ports screen.

2.

In the Management Window, click the Alerts tab.

The Alerts tab appears as follows:

Viewing System Ports 109

Advertising