5.4. Selecting the display channel

1. Prior to selecting a channel to be displayed you must first tell the system what channels are available.

With your MTS chain connected together connect the serial OUT of the last XD-16 to your computer and
launch LogWorks.


2. Make sure that all your channels are setup properly (go into Channels/Configure Channels).

3. Once you have all your gauges setup properly in LogWorks you may exit the application and power the

MTS system down.

4. Remove the XD-16 which you want to reprogram from the MTS serial chain. Insert the terminator plug in

the serial IN of the XD-16 and the cable that goes to the computer to the serial OUT. Launch LM
Programmer.

5. Once in LM Programmer go to the "Input" tab. The LM Programmer will read the MTS record. You will

now be able to select the channel that you want the XD-16 to display.


If you select something other than a Lambda/AFR channel, the display will change to:

As you can see here, the display will indicate in 100 RPM. This might be too coarse for many applications. The
limit is there because the XD-16 can only display 3 digits. By applying a limit (for example to 0…9990 RPM the