Forced activation test – Nitrous Express DRAG-SPORTSMAN N2O User Manual

Page 10

Advertising
background image


9

Davis Technologies TM-Drag-Sportsman-MAP V3 2010

and the unit will make a large correction.

Forced Activation Test:

This test is useful to check the cut function. The
progressive controller must be configured prior to
executing this test

.

(Activate the “Traction Control”

option in the progressive controller’s software, and
set the ramp to 100%, and uncheck the “RPM
Connected” box for this test).

This is also useful to

test the connections to a data system if used.

1.

Set the “Setup” dial to any setting between 1
to 8.

2.

Turn “on” the power to the unit, the LED
should begin to flash.

3.

Arm the nitrous system,

with the Fuel

and Nitrous systems de-pressurized

!

(Close the bottle valve, disconnect the fuel

pump power, and purge both systems).

4.

With the engine off; activate the full throttle

switch and trans brake, if used, to start the

progressive controller’s cycle.

Quickly

press the Test button on the unit until

the LED glows solid.

The cut will activate for 4 seconds.

(You will

hear the solenoids change sound as the
ramp is cut).

The data output wire (pink) will also be on for
the 4 seconds of the test.

Note: After the test is complete, the LED will blink to

show the firmware version.

Advertising