Checking settings – Nitrous Express DRAG-SPORTSMAN N2O User Manual
Page 17

16
Davis Technologies TM-Drag-Sportsman-MAP V3 2010
The current setting for the different adjustments can
be verified at any time using the Test button and the
LED. This process is divided into 2 sections.
Standard, and Advanced. The different sections are
chosen by the position by the dial when the
verification is started.
Checking Settings:
The Standard values can be verified at any time by
following these steps.
1.
Turn the power “On”
2.
Set “Setup” dial any position from 1-7.
3.
Press the “Test” button and HOLD
DOWN.
4.
The LED will glow solid for 8
seconds (as in the Forced Activation Test),
then blink to show the firmware version.
5.
Next the LED will flash the value for the
Buffer.
(A setting of zero is indicated by a
short blip of the LED).
6.
After a short pause, the Led will flash for the
value of Sample Rate, followed by a pause.
8.
Lastly, the LED will Flash the current Self
Learning status value.
(For tech support purposes only)
The Advanced values can be verified at any time by
following these steps.