Enable First-Gear Lockout disables the stage until the RPM has exceeded the RPM Cutoff at least
once since it was powered on.

T-Brake will determines what effect the trans-
brake will have on the applicable stage. Arm
allows the stage to function normally while
Disarm turns the stage off. If you are not using
this input set it to Do NothingTo.

RPM Cutoff allows you to set the upper RPM
threshold above which the nitrous will be
turned off. If you remove the check mark the
nitrous will not turn off at the cutoff.

RPM Trigger allows you to set the minimum
RPM required before the Nitrous can be
triggered.

Delay sets the time that the controller will delay starting the ramp once a stage has been triggered

RAMP TIME sets the build time for the ramp

Start sets the start percentage of the stage.

Final sets the final percentage of the stage. The ramp will maintain this level until the RPM cut-off is
reached or the stage is deactivated by the TPS or RPM window.

Solenoid Frequency sets the rate at which the controller will pulse the solenoids. 14 hz works with
most solenoids.