Chapter 4 ________________________________________________________________ Operation

VAISALA_______________________________________________________________________ 45

WS Command

This command requests the verbose Built-In Test (BIT) results. The
command format is:

WS CR LF

The command gives a textual run down of the results of all Built-In
Tests (BITs). In every line except the bad reading counter, the pass/fail
indication is given with the single character P or F. This is followed by
the description of the parameter measured, which is followed by the
actual measured value. The Bad 1 second readings counter is a running
total of the number of fundamental 1 second readings that were flagged
as bad by the sensor. This number rolls over to zero after reaching a
count value of 65535. It is initialized to zero on each power-up or any
other activity that performs a re-initialization of the sensor.

The time measurement quality indices are given for path numbers
defined as follows:

-

Path 0 is from south transducer to north transducer

-

Path 1 is from north transducer to south transducer

-

Path 2 is from north transducer to east transducer

-

Path 3 is from east transducer to north transducer

-

Path 4 is from east transducer to south transducer

-

Path 5 is from south transducer to east transducer

A listing for the command response is given below with representative
values.

CR LF

P Heater voltage 22.3 Volts CR LF

P Array heater resistance 4.9 Ohms CR LF

P Heaters off voltage 0.1 Volts CR LF

P Incoming supply voltage 12.2 Volts CR LF

P 5.0 volt supply 5.05 Volts CR LF

P 10 volt supply 10.2 Volts CR LF

- Bad 1 second reading counter 0 CR LF

P Path 0 signal quality index 99 CR LF

P Path 1 signal quality index 99 CR LF

P Path 2 signal quality index 99 CR LF

P Path 3 signal quality index 99 CR LF

P Path 4 signal quality index 99 CR LF

P Path 5 signal quality index 99 CR LF