2 connecting the sensors, 2 connecting the sensors -10, Operating instructions arimetec – ARI Armaturen ARImetec-S EN User Manual
Page 10: S 6.2 connecting the sensors
![background image](/manuals/409403/10/background.png)
Page 2-10
Rev. 0040807015 1014
Operating Instructions
ARImetec
®
-S
6.2 Connecting the sensors
Connect the required sensor to the ARImetec
®
-S , depending on the application (refer to
section "5.2 Using the sensors").
Steam traps can be tested with the structure-borne sound sensor and the surface
temperature sensor.
Sound-insulated headphones are recommended for leakage detection, especially if loud
ambient noise levels are likely. Make sure the headphones are plugged securely into the
socket.
g) Re-insert the battery compartment in the
housing.
h) Tighten the locking screw of the battery
compartment again.
i) Fasten the shoulder strap to the lid of the
battery compartment.
Connection for structure-borne sound sensor
Connection for headphones
Connection for temperature sensor