Digital recorder – Videoswitch Vi605 User Manual

Page 43

Advertising
background image

Digital Recorder

39

Pull-Up and Restore

This part of the menu deals with the pull-up of a camera on a monitor under alarm
conditions.

Pull-Up Monitor

Specify here on which monitor an alarm camera should be displayed.

Pull-Up Hold Time

When an alarm condition occurs the associated camera is displayed for this hold time, even
if other cameras also have alarms meanwhile.

If other cameras have alarms these will then be displayed in turn, each one being shown for
the specified hold time.

[0..9] Enter hold time

[<][>][^][v] Change hold time

[Tag] set default hold time

Sequence Time

When multiple alarmed cameras exist, once the hold time has elapsed for each, they will
start sequencing with a programmable sequence time.

[0..9] Enter sequence time

[<][>][^][v] Change sequence time

[Tag] set default sequence time

Relay Hold Time

Whenever an alarm, activity or wireless PIR event occurs, the alarm relay activates. When
all alarm conditions have cleared, the relay will stay activated until the relay hold time has
expired.

When the record rate is modified by alarms, this condition will also apply until the alarm
relay deactivates.

[0..9] Enter relay hold time

[<][>][^][v] Change relay hold time

[Tag] set default relay hold time

Restore Camera

Following the pull-up of one or more alarmed cameras, this setting determines whether the
original pre-alarm camera is restored, or whether the last alarmed camera is left on the
monitor.

[^][v] Select whether pre-alarm camera is restored

Restore Tour1

This setting determines whether Tour1 is invoked when an alarm condition clears.

[^][v] Select whether Tour1 is restored

Restore Preset1

This setting determines whether Preset1 is invoked when an alarm condition clears.

[^][v] Select whether Preset1 is restored

Advertising
This manual is related to the following products: