7.2.4 Video cable connection

h

The installation is type CDS (Cable
Distribution System), do not connect it to
SELV circuits.

h

In order to reduce the risk of fire, only
use cable sizes greater than or equal to
26AWG.

h

Connect the screen and central cable
respectively to the GND and VIDEO
terminals. The terminals accept cables
with sections between 0.5 mm2 (AWG20)
and 0.08 mm2 (AWG28).

GND

VIDEO

Signal

Fig. 35

7.2.3.2 Power supply connection 24Vac

Connect the power supply cables as described in the
table below.

POWER SUPPLY CONNECTION 24VAC

Colour

Terminals

Defined by the installer

(N) Neutral

Defined by the installer

(L) Phase

Yellow/Green

Earth

Tab. 04

h

Only for products marked UL intended for
the North American market, use a class 2 UL
listed transformer.

7.2.3.3 Power supply connection
120/230Vac

Connect the power supply cables as described in the
table below.

POWER SUPPLY CONNECTION 120/230VAC

Colour

Terminals

Blue

(N) Neutral

Brown

(L) Phase

Yellow/Green

Earth

Tab. 05

h

Use the appropriate junction-box
UPTJBUL t
o connect the power supply
line. For further information, refer to the
product use and installation manual.