ZONE TITLING
------------------------
1>NR. : 1
2 ENAB.: N
3 START: + 0.00
4 STOP : + 0.00
5 TEXT : ZONE 1

Fig. 73

Example: To enable titling of zone 1 when the device
is between +15° and +45°, it is necessary to:
• Enable area titling by setting Y as the value of

Enabling.

• Set 1 as the value of parameter Nr.
• Set +015.00 as the value of parameter Start.
• Set +045.00 as the value of parameter Stop.
• If necessary, edit the displayed text by selecting

Text.

j

Setting the Start and Stop values of the
menu to zero will disable text display. If
there are overlapping areas, the area with
the lowest number will prevail.

j

To define zones proceed in a clockwise
direction, as shown in the figure.

Start1=15°

Stop1=45°

Start2=170°

Stop2=225°

270°

90°

180°

Fig. 74

9.6.3 ZFI camera settings menu

01. Zoom: This sets the maximum zoom level that

the motorised lens can achieve.

02. Common Wire: If enabled, it manages the

motorised common wire lenses; if disabled, it
manages those with inversed polarity.

04. Area Titling: Allows access to the area titling

submenu.

05. Zone Masking: This provides access to the zone

masking management submenu.

06. Housing Serial Port: Allows access to the

submenu for managing the housing serial port.

07. Polarity: Allows access to the submenu for

managing the polarity of the Zoom, Focus and
Iris motors.

ZFI CAMERA SETTINGS
------------------------
1>ZOOM : 30x
2 COMMON WIRE : N

4 ZONE TITLING >
5 ZONE MASKING >
6 HOUSING SERIAL PORT >
7 POLARITY >

Fig. 72

9.6.3.1 Zone titling menu

This function allows setting up to 8 areas (variable
dimension) with titling option.
From the Zone Titling menu it is possible to set the
following parameters:
01. Number: Selects the area to be edited.
02. Enabling: Enables the message linked to the

related zone to be displayed on the screen.

03. Start: Sets the initial position of the area.
04. Stop: sets the final position of the area.
05. Text: Modifies the text which is displayed when

moving within the zone.