Bluetooth MagneSafe V5 Swipe Reader


22

COMMAND NUMBER

This one-byte field contains the value of the requested command number. The following table
lists all the existing commands:

Value
(Hex)

Command Number

Description

00

Get Property

Gets a property from the reader

01

Set Property

Sets a property in the reader

02

Reset Device

Resets the reader

09

Get DUKPT KSN

Reports DUKPT KSN and Counter

0A

Set Session ID

Sets the current Session ID

10

Activate Authenticated
Mode

Starts Activation of Authenticated Mode of
secure operation

11

Activation Challenge Reply
Command

Completes the Activation of Authenticated Mode
of secure operation

12

Deactivate Authenticated
Mode

Deactivates the Authenticated Mode of secure
operation

13

Reserved

14

Get Reader State

Gets the current state of the reader

15

Set Security Level

Sets or gets the current Security Level

25

Relinquish Interface

Makes reader receptive to commands on either
Bluetooth or USB interface.

28

Power Down MSR

Powers down the MSR circuits (if running on
battery turns reader off).

29

Get Battery Status

Gets Charge Status of battery


DATA LENGTH

This one-byte field contains the length of the valid data contained in the Data field. For
example, a command with one byte of data would send 01 for this byte; a command with 18
bytes of data would send 12 for this byte.

DATA

This multi-byte field contains command data if any. Note that the maximum length of this field
is fixed at 60 bytes. Valid data should be placed in the field starting at offset 2.

RESULT CODE

This one-byte field contains the value of the result code. There are two types of result codes:
generic result codes and command-specific result codes. Generic result codes always have the
most significant bit set to zero. Generic result codes have the same meaning for all commands
and can be used by any command. Command-specific result codes always have the most
significant bit set to one. Command-specific result codes are defined by the command that uses
them. The same code can have different meanings for different commands. Command-specific
result codes are defined in the documentation for the command that uses them. Generic result
codes are defined in the following table.

Value (Hex)

Result Code

Description

00

Success

The command completed successfully.

01

Failure

The command failed.

02

Bad Parameter

The command failed due to a bad parameter or
command syntax error.

05

Delayed

The request is refused due to anti-hacking mode

07

Invalid Operation

Depends on context of command