Stay powered after swipe property, Interface type property, Track data send flags property – MagTek Bluetooth MagneSafe V5 Swipe Reader User Manual

Page 37

Advertising
background image

Section 5. Communications

29

STAY POWERED AFTER SWIPE PROPERTY

Property ID:

0x0E

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x00 (Don’t Stay Powered)

Description:

This property controls whether the reader stays powered after a good swipe.
If the property value is 0x00 (the default), the reader powers down after a
good swipe.

If the property value is 0x01, the reader stays powered after a good swipe. In
this case, the reader may be powered down by the user pressing and holding
the User Switch or it will time out eventually.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


INTERFACE TYPE PROPERTY

Property ID:

0x10

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

No

Default Value:

3 (Indicates Bluetooth interface)

Description:

The value is a byte that represents the reader’s interface type. It is always set
to 3 indicating this is a Bluetooth reader.


Example Get Interface Type property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

10


Example Get Interface Type property Response (Hex):

Result Code Data Len

Prp Value

00

01

03


TRACK DATA SEND FLAGS PROPERTY

Property ID:

0x14

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x63

Description:

This property is defined as follows:

ICL

SS

ES

LRC

0

LC

Er

Er

Advertising