Post card string property – MagTek Bluetooth MagneSafe V5 Swipe Reader User Manual

Page 40

Advertising
background image

Bluetooth MagneSafe V5 Swipe Reader


32

Example Set Pre Card String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Pre Card String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1E


Example Get Pre Card String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33


POST CARD STRING PROPERTY

Property ID:

0x1F

Property Type:

String

Length:

0 – 7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

The default value is no string with a length of zero.

Description:

The value is an ASCII string that represents the reader’s post card string. This
string can be 0 – 7 bytes long. This string is sent after all other card data.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


Example Set Post Card String property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

04

1F

31 32 33


Example Set Post Card String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Post Card String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1F


Example Get Post Card String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33

Advertising