Example Set Post Track String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Post Track String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

21

Example Get Post Track String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33


TERMINATION STRING PROPERTY

Property ID:

0x22

Property Type:

String

Length:

0-7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

0x0D (carriage return)

Description:

This string is sent after the all the data for a transaction. The string can be 0 –
7 bytes long. If the value is 0 no character is sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


FS PROPERTY

Property ID:

0x23

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x7C (‘|’)

Description:

This character is sent as the field separator to delimit additional data
(MagnePrint info, reader info, DUKPT info, etc.). If the value is 0 no
character is sent. If the value is in the range 1 – 127 then the equivalent
ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.