Assigning Lines

Quick Reference Guide

Automatic Daylight/Standard Times (#126)

Available in Release 3.0 or later systems, this feature is turned on by default and
automatically updates the system clock for annual Daylight Savings Time and
Standard Time changes. If you are in an area that does not have daylight savings
time, use the procedure below to turn off this feature.

To change the status of Automatic Daylight/Standard Time:

1

Press

f00ss#126

at extension

10 or 11.

2

Press

D

until the appropriate value appears:

• 1 = Active (the factory setting)

• 2 = Not Active

3

Select another procedure, or exit programming mode.

Assigning Lines

Use the feature Number of Lines (#104) to determine in Key mode the number of
outside lines that are automatically assigned to all system extensions, or to
determine in Hybrid mode the number of lines assigned to the main pool. After
you use the Number of Lines feature, you can use other features to refine the
assignment of lines.

Line assignment is also based upon whether an extension is a Key or Pooled
extension. Refine the line assignment accordingly after you use the Number of
Lines feature.

CAUTION:

Do not use Number of Lines (#104) after initial setup.

Refer to the PARTNER Advanced Communications System Installation,
Programming, and Use
guide for more detail.