Install attachment sets, Operation – Karcher IP 120 User Manual

Page 13

Advertising
background image

English

13

Warning

Installation sets must only be installed by
authorized personnel.

ƽ

Danger

Risk of injury on account of electric shock.
Pull the plug out of the socket before open-
ing the control cabinet.
Î

Open the switch cabinet locks, swivel
cover upward and latch.

1 Lock
2 Nut
3 Cover

Î

Remove the nuts on the cover.

Î

Remove cover.

Î

Insert the control and fasten it with
screws.

1 Dummy connector
2 Power strip

Î

Pull the dummy connector out of the
power strip.

Î

Insert the control plug instead of the
dummy connector.

Î

Install the scale platform below the pel-
let ejector and level.

Note
Make sure that the scale platform is free-
standing and not obstructed by any objects,
as this will cause inaccurate measure-
ments.
Î

Open both latches on the front machine
cover.

Î

Tilt the cover toward the outside and lift
off from the top.

1 Plug

Î

Guide the scale platform cable into the
machine from the bottom and connect
the plug on the bottom of the switch
cabinet.

Î

Close and lock the machine cover.

The volume control is installed just like the
control of the installation set "Scale".
The scale does not need to be connected.

ƽ

Danger

Risk of suffocation on account of carbon di-
oxide. The carbon dioxide content in the air
at the place where the machine is used will
increase when the machine is running. En-
sure adequate ventilation at the place of
use; if possible, use an alarm to warn per-
sons. Symptoms of high levels of carbon di-
oxide in the air that is breathed in:
3...5%: headache, faster breathing.
7...10%: headache, nausea and per-

haps even unconsciousness.

If any of these symptoms occur, please
switch off the machine immediately and get
a breath of fresh air and improve the venti-
lation before starting work again with the
machine.
Follow the safety specifications of the man-
ufacturer of carbon dioxide.

ƽ

Danger

Risk of cold burns. Dry ice has a tempera-
ture of -79 °C. Never touch dry ice or cold
parts of the machine without appropriate
protection. Wear protective gloves and pro-
tective overalls.

ƽ

Danger

Risk of injury on account of ejected dry ice
pellets. Inspect the pellet ejector for cleanli-
ness prior to taking it into operation. Do not
look directly at the extruder plate.

ƽ

Danger

Danger of bursting. Never store dry ice in
tightly sealed containers.
Î

Set the key switch "M/0/A" to "A". Re-
move the key and store so that it can
only be accessed by service personnel.

Î

Switch on the power supply.

Î

Open the carbon dioxide supply.

Î

Turn on the main switch.

Î

Release emergency-stop button by
turning.
The indicator lamp "Voltage on" will illu-
minate.

Î

Place an empty container below the pel-
let ejector.

Î

If the installation set "Scale" has been
installed, set the key switch "On/Off" to
"Off".

Î

If the installation set "Volume control"
has been installed, set the key switch
"Direct/PCS" to "Direct".

Î

Press "On" key.
The pellet production will start.

Î

Once the desired quantity of pellets has
been produced, press the "Off" key.
The machine will finish the current pro-
duction cycle and will then terminate the
pellet production.

In automatic mode, a preset quantity of pel-
lets is produced. After that, the machine will
terminate the pellet production.

1 Display
2 "F" key

Î

Set the key switch "0/OFF" / "I/ON" to
"1/ON" (option).

Î

Center an empty container on the scale
platform.

Î

Read its empty weight (in kg) on the dis-
play.

Î

Press "F" key.

Î

Set its empty weight (in kg) on the dis-
play using the arrow keys.

Î

Press "F" key until "CF" is shown on the
display.

Î

Release the "F" key and press it once
again.
The display shows "H1" and the set
empty weight (alternating).

Î

Set the pellet quantity to be produced
(in kg) on the display using the arrow
keys.

Î

Press "F" key until the empty weight is
shown on the display.

Install attachment sets

Mounting the installation set scale

(option)

Installing the control

Connecting the scale

1

2

3

Mounting the installation set "Vol-

ume control PCS" (option)

Operation

Start up

Manual operation

Automatic operation with the instal-

lation set "Scale" (option)

Setting the quantity to be produced

Advertising
This manual is related to the following products: