Advanced operation, Sensor adjustment (ra- dar sensor) – Alpine SEC-8058 User Manual

Page 86

Advertising
background image

86

English

Advanced
Operation

Sensor Adjustment (Ra-
dar Sensor)

Remove the key from the ignition.

Turn the Disarm/Valet switch ON and hold it
for one second.
The extension LED will glow for one second.

Press and release the TX/PANIC and EXT1/
VALET buttons simultaneously.
"EXTERIOR RADAR ADJ" will appear on the
remote control transmitter. The system is in
exterior radar sector adjustment mode.

Press and release the TX/PANIC or EXT1/
VALET button to make the sensitivity
adjustment (outside of the vehicle).
A number from 1 to 15 will appear represent-
ing the amount of radar sector coverage. "1"
is the least coverage while "15" is the most
coverage. When finished adjusting the
exterior radar sector coverage, proceed to
step

5

.

TX/PANIC button: UP
EXT1/VALET button: DOWN

Note: If sensed, the Extension LED will blink

6 times.

3.$

1

2

VALET

3

4

and/et/y

E

X

T

1

/V

A

L

E

T

TX

PANIC

(SEA-8481)

(SEA-8481)

TX

PANIC

or/ou/o

E

X

T

1

/V

A

L

E

T

EXTER

01

EXTERIOR RADAR ADJ

01~15

ACC

OFF

ON

RUN