M414462

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming the Electronic OPL Control

Figure 9

Drying can be done automatically or by time dry.
When drying automatically, the tumbler stops drying
when laundry reaches the factory set or programmed
dryness level and starts cool down. When time drying,
the tumbler stops drying when programmed time ends
and starts cool down.

Both automatic and time dry have factory-set cycles,
but other cycles can also be created. Frequently used
cycles can be saved in the control’s memory as Custom
cycles.

In all cycles, except No Heat, Wrinkle-Free begins
when Cool Down ends. During Wrinkle-Free, the
tumbler alternately stops for 2-1/2 minutes and then
runs without heat for 2-1/2 minutes until door is
opened or 60 minutes has elapsed.

The HIGH, MEDIUM, MED LOW, and LOW ON/
SELECT pads may be saved in one of four ways as a
custom heat cycle, refer to Table 1.

Table 1

T359I

NOTE: Not all tumblers will have reversing option.

STATUS

DRYING

COOL DOWN

DOOR OPEN

CUSTOM

HIGH

MEDIUM

MED LOW

LOW

NO HEAT

TEMP

DISPLAY

SIGNAL

F/ C

TEMP

PROGRAM

AUTO

SPECIAL

CYCLE

MORE

CONDITION

SPECIAL

TIME

COOL

DOWN

LESS

SAVE

CUSTOM

TIME

*

+

-

-

*

PROG

AUTO

AUTO

ON / SELECT

START

STOP/RESET

REVERSING

T359I

One pre-programmed
NO HEAT cycle

Four pre-programmed
Automatic Dry heat
cycles

All of these cycles
may be used as
pre-programmed
from the factory . . .

They may be
modified for one
cycle without
being saved in
the memory . . .

They may be
modified and
saved in the
memory as one of
five CUSTOM
CYCLES.

OR

OR

Custom Cycles

Automatic Dry

Dries the load to one of eleven user-
selectable dryness levels for a given
fabric type, and then enters automatic
or user-variable cool down.

Time Dry

Duplicates the functions of
electromechanical dual timer
controls, allowing the user to vary
temperature, drying time and cool
down time.

Special Cycle

Allows the user to specify the
number of heating cycles and to
select from the full range of
temperatures for all heat cycles.

Special Time

Similar to Time Dry, except that the
user may specify from 80°F (27°C)
to 180°F (82°C) for any heat cycle.

Advertising