Temperature sensor, Temperature adjustment, Temperature display (°f/°c) – Alliance Laundry Systems T453I User Manual

Page 27: Cylinder temperature display

Advertising
background image

Programming the Electronic OPL Control

25

M414462

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Temperature Sensor

To test the temperature sensor, hold COOL DOWN
pad and press the TEMP pad in the idle mode. This
will show the temperature detected by the control.

“SH” displays and signal sounds if the temperature
sensor is shorted or sensor temperature is over 200°F
(93°C). Press the STOP/RESET pad twice within 3
seconds and allow the tumbler to cool, then press an
ON/SELECT pad. If “SH” still displays, call for
service.

“OP” displays and signal sounds 3 minutes after the
tumbler is started if the temperature sensor is faulty or
if a temperature below 24°F (-4.4°C) is detected. If
dryer temperature is above 24°F (-4.4°C), call for
service.

NOTE: To display the software revision level, hold
the AUTO pad and press the TIME pad while the
control is in idle mode.

Temperature Adjustment

Selecting a fabric type selects a preset ideal
temperature for that fabric. Lower temperatures may
be needed for small loads or when air flow through the
tumbler is less than ideal due to inadequate make-up
air or exhaust ducting.

Whenever the control is on, but not in NO HEAT,
COOL DOWN or LOAD READY, pressing the TEMP
pad displays the three digits of the set temperature.
Use the MORE or LESS pad to increase or decrease
the temperature.

Temperature Display (°F/°C)

To select between Fahrenheit and Celsius display, hold
in the TEMP display pad while pressing the TEMP
pad.

NOTE: Temperature can be set from 80°F (27°C)
to 180°F (82°C) in the SPECIAL CYCLE and
SPECIAL TIME options only.

To include an adjusted temperature in a Custom cycle,
simply adjust temperature before pressing CUSTOM.

Cylinder Temperature Display

To see the approximate temperature at the exit of the
cylinder, press and hold the TEMP DISPLAY pad
(50-170# Models Only).

Table 4

Temperature

Selection

Control

Program

Temperature

Desired
Clothes

Temperature

°F (°C)

°F (°C)

0220S
0270S

0350S

0220S
0270S

0350S

140 (60) 145 (63) 185 (85) 190 (88)

135 (57) 140 (60)

180 (82)

HIGH

130 (54) 135 (57) 170 (77) 175 (79)

125 (52) 130 (54) 160 (71) 165 (74)

120 (49) 125 (52) 155 (68) 160 (71)

125 (52) 130 (54) 160 (71) 165 (74)

120 (49) 125 (52) 155 (68) 160 (71)

MEDIUM

115 (46) 120 (49) 150 (66) 155 (68)

110 (43) 115 (46)

145 (63)

105 (41) 110 (43) 135 (57) 140 (60)

110 (43) 120 (49) 145 (63) 155 (68)

105 (41) 115 (46) 135 (57) 145 (63)

MED LOW

100 (38) 110 (43) 130 (54) 140 (60)

95 (35)

105 (41) 120 (49) 135 (57)

90 (32)

100 (38) 105 (41) 125 (52)

95 (35)

120 (49)

90 (32)

105 (41)

LOW

85 (29)

100 (38)

80 (27)

95 (35)

75 (24)

95 (35)

Advertising