Basic control system troubleshooting, Low voltage, Brown outs – Balboa Water Group BP 50Hz User Manual

Page 13: Checking the system power input fuse warning

Advertising
background image

13

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

42217B

LOW VOLTAGE

At Balboa, it’s been our experience that the majority of the
problems associated with electronic control systems are due
to low voltage.

BROWN OUTS

“Brown outs” can have an effect on the spa’s operation in
a variety of ways. The control panel may go blank, have
scrambled messages on the LCD, or only a few features
will function.

CHECKING THE SYSTEM POWER INPUT FUSE

WARNING

These procedures are performed while the system is
powered up and running under peak loads. Be careful.

Systems that use 230V peripheral devices (below):

Measure between the brown TB1 terminal and F6 power

input fuse at F6. You should see 230 volts.
If you determine that there is no voltage at this location,

then the system power input fuse needs to be replaced.
Only use a fuse of the same type and amp rating when
you replace any of these fuse.
NOTE FOR ALL SYSTEMS

In each situation, the most

likely reason for the system power input fuse to blow is
a pump problem. (cont. next page)

Once the power input fuse has been changed

Check the voltage between the black and red

wires again. Acceptable voltage range is between
216V and 264V.

If the system is getting the proper voltage at
TB1, but still doesn’t operate, then test for a
blown power input fuse.

Basic Control System Troubleshooting

F6 Fuse

Terminal Block & F6

Fuse on a BP2100 Board

TB1

Terminal Block & F6 Fuse on a

BP600 Power Board, 230V Setup

Note: Local codes and laws vary. Use information below as a guide.

L2

L1

N

T 150mA 250V

F6

J44
J48

J1
J2

J24

J45

J49

J15

F5 T 30A

GND

K3

K5

K6

K1

22117_B

HTR A

HTR B

UNFUSED

GRN

N

L1

N/A

ADDED JUMPER FOR

CE INSTALLATIONS

BLU

BRN

J25=HTR1

J26=HTR2

J27=HTR3

J30=TEST

J31=CE

HTR

SEL

TB1

K2

K4

J9

1

2

3

4

4

J45

J110

J79 J54

J72 J42

J37 J4

J77 J75 J78

J36

J60

J46

J

J

J53

J

J41

J12

F6 30A

J56 J57

J55

J59

J51 J52

PUMP 1

GRN

BLU

BRN

Advertising