Caution - test is with power on – Balboa Water Group BP 50Hz User Manual

Page 33

Advertising
background image

33

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

42217B

Testing Low Speed and High Speed at the AMP Pump Connector

WITH THE PUMP LOW SPEED ON,

TAKE A VOLTAGE READING AT THE

AMP RECEPTACLE ON THE PCB

THIS WOULD TYPICALLY SHOW LOW

SPEED VOLTAGE FOR PUMP ONE. (230V)

WITH THE PUMP HIGH SPEED ON,

TAKE A VOLTAGE READING AT THE

AMP RECEPTACLE ON THE PCB

THIS WOULD TYPICALLY SHOW HIGH
SPEED VOLTAGE FOR PUMP ONE. (230V)

Ground

Neutral (Common)

Typically Line voltage for 2-speed pumps

Typically Line voltage

Note flat sides in connector

Board Connector Key

Note: These are typical settings only.

Voltages may be different depending

on the configuration that the system is

set to. See the system's Tech Sheet for

more information.

PUMP 1 AMP CORD

TESTING LOW SPEED AND HIGH SPEED AT THE AMP CONNECTOR

CAUTION - TEST IS WITH POWER ON