Balboa Water Group BP 50Hz User Manual
Page 66

66
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
5/02/13
W
iri
ng Diagr
am - BP2
1MSSH, Par
t Number
: 563
81 (
con
t.)
PART B
BP21MSSH – PN 56381
01-03-13
1
PROGRAMMABLE FILTRATION + POLLING
2-SPEED
2-SPEED
1-SPEED
°C
2
PROGRAMMABLE FILTRATION + POLLING
2-SPEED
1-SPEED
1-SPEED
°C
3
PROGRAMMABLE FILTRATION + POLLING
2-SPEED
NONE
1-SPEED
°C
4
NONE
2-SPEED
2-SPEED
1-SPEED
°C
5
NONE
2-SPEED
1-SPEED
1-SPEED
°C
6
NONE
2-SPEED
NONE
1-SPEED
°C
SETUP #
CIRC PUMP
PUMP 1
PUMP 2
MicroSilk®
TEMP SCALE
PUMP 1 LOW TIMEOUT IS 15 MINUTES.
LOCATION DEVICE
J9
NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPEED PUMP 1
J14
NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 2 ALIMENTATION POMPE 2 A 2 VITESSES 2-SPEED PUMP 2
PUMP 2 LINE 1 CONNECTION
J19 to J57
J15
10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT
J21
KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP
J32
OZONGENERATOR GENERATOROZONE OZONE GENERATOR
CIRC AND OZONE LINE 1 CONNECTION
J81 to J55
J33
TV / AV
J40 IR
RECIEVER
J5, J8
AUX PANEL(S) - AX10, AX20, AX30, AX40
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
SWITCHBANK S1 OFF
SWITCHBANK S1 ON
SWITCHBANK S1 OFF
SWITCHBANK S1 ON
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
230V 3þ / 3x16A
230V 3þ
3x16A
GRN
BLU
1 BRN
2 BRN
3 BRN
PUMP 2 IS 2-SPEED IN
SETUPS 1 & 4
PUMP 2 IS 1-SPEED IN
SETUPS 2 & 5
PUMP 2 IS NOT USED IN
SETUPS 3 & 6
SINGLE SERVICE
230V 1þ / 1x32A,
THREE-SERVICE
230V 1þ / 3x16A
230V 1þ
1x32A
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A*
STORE SETTINGS**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B*
MEMORY RESET**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
**SWITCH #
6
SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
**SWITCH #
6
SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 4 HS PUMPS W/HTR
SPECIAL AMPERAGE RULE A*
STORE SETTINGS**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 4 HS PUMPS WITH HEAT
SPECIAL AMPERAGE RULE B*
MEMORY RESET**
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
NOT ASSIGNED
SYSTEM WILL BE IN SETUP #1
UNLESS MARKED OTHERWISE
INSTEAD OF SETUP #1,
THIS SYSTEM IS CONFIGURED IN SETUP #:
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE.
TB1
1
2
3
4
4
3
2
1
J78
J45
J79
J72
J42
J3
J37
J4
J1
J61
J47
J54
J77
J75
J36
J60
J53
J58
J41
J12
J88
J62
J51
J52
J98
J38
J6
W1-XP332
XP332
J20
J18
J46