Balboa Water Group BP 50Hz User Manual
Page 28

28
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
5/02/13
Testing Pump Fuses for Damage with Voltage On - BP2100
TEST THE VOLTAGE FROM THE
RIGHT SIDE OF THE FUSE
TEST THE VOLTAGE FROM THE
LEFT SIDE OF THE FUSE
THERE ARE THREE 30A PUMP FUSES IN THE BP2100G1 SPA CONTROL SYSTEM.
F6 AND F8 ARE ON THE MAIN BOARD. F1 IS LOCATED ON THE EXPANDER BOARD.
CAUTION - TEST IS WITH POWER ON
230V on each side
indicates a good fuse
230V on one side and
0V on the other side
indicates a bad fuse
Then continue
measuring the other
two fuses: F8, F1
F6 TO TB1 BLUE
F6
F8
F1