Balboa Water Group BP 50Hz User Manual

Page 64

Advertising
background image

64

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

5/02/13

W

iri

ng Diagr

am - BP2

100G

1,

Par

t Number 563

89-0

1 (

con

t.)

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

SWITCHBANK S1 OFF

SWITCHBANK S1 ON

PART B

GRN

BLU

1 BRN

2 BRN

3 BRN

TB1

1

2

3

4

4

3

2

1

J78

J45

J79

J72

J42

J3

J37

J4

J1

J61

J47

J54

J77

J75

J36

J60

J53

J58

J41

J12

J88

J62

J51

J52

J98

J38

J6

J1

J46

01-30-13

BP2100G1 – PN 56389-01

1

NONE

2-SPEED

2-SPEED

2-SPEED

NONE

°C

2

NONE

2-SPEED

2-SPEED

1-SPEED

NONE

°C

3

NONE

2-SPEED

2-SPEED

NONE 1-SPEED °C

4

NONE

2-SPEED

2-SPEED

NONE NONE °C

5‡

NONE

2-SPEED

1-SPEED

1-SPEED

1-SPEED

°C

6

NONE

2-SPEED

1-SPEED

1-SPEED

NONE

°C

7

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

2-SPEED

NONE

°C

8

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

1-SPEED

NONE

°C

9

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

NONE

1-SPEED

°C

10

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

NONE

NONE

°C

11‡

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

1-SPEED

1-SPEED

1-SPEED

°C

12‡

PROGRAMMABLE FILTRATION + POLLING

1-SPEED

1-SPEED

1-SPEED

1-SPEED

°C

13

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

1-SPEED

1-SPEED

NONE

°C

14

PROGRAMMABLE FILTRATION + POLLING

1-SPEED

1-SPEED

1-SPEED

NONE

°C

15‡***

NONE

2-SPEED

2-SPEED

1-SPEED

1-SPEED

°C

16‡***

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

1-SPEED

1-SPEED

°C

17

PROGRAMMABLE FILTRATION + POLLING

1-SPEED

1-SPEED

NONE

1-SPEED

°C

18

NONE

2-SPEED

1-SPEED

NONE 1-SPEED °C

***SETUPS 15 AND 16 REQUIRE ADDITIONAL FUSED ADAPTER FOR BLOWER OUTPUT

SETUP #

CIRC PUMP

PUMP 1

PUMP 2

PUMP 3

BLOWER

TEMP SCALE

INSTEAD OF

SETUP #1,

THIS SYSTEM IS

CONFIGURED IN

SETUP #:

PUMP 1 LOW TIMEOUT IS 15 MINUTES.

FOR SUPPLY CONNECTIONS,

USE CONDUCTORS SIZED ON THE

BASIS OF 60°C AMPACITY BUT

RATED MINIMUM OF 90°C.

TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)

USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE.

LOCATION DEVICE

J9

NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPEED PUMP 1

J14 AUX**

AUX LINE 1 CONNECTION

J19 to J43

J15

10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT

J21

KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP (SETUPS 7-14, 16)

J32

OZONGENERATOR GENERATOROZONE OZONE GENERATOR

CIRC AND OZONE LINE 1 CONNECTION

J81 to J59

J33

TV / AV

J40 IR

RECIEVER

J5, J8

AUX PANEL(S) - AX10, AX20, AX30, AX40

SINGLE SERVICE

230V 1þ / 1x32A,

THREE-SERVICE

230V 1þ / 3x16A

‡SETUPS 5, 11, 12, 15 AND 16 REQUIRE BP2X-WIRE KIT PN30893

TO

J1 ON

EXPANDER

TO RED AC (GROUP 2)

ON MAIN BOARD

SPLITTER OPTIONS:

IN SETUPS 5, 11, 12 S1 = PUMP 2 S3 = PUMP 3

IN SETUPS 15, 16 S1 = PUMP 3 S3 = FUSED ADAPTER

SPLITTER IS UNUSED (REMOVED) IN SETUPS 1-4, 6-10, 13, 14, 17, 18

WHITE

RED

WHITE

GREEN

GREEN

BLACK

S1

12A MAX

S2

12A MAX

‡ OPTIONAL BP2X-WIRE KIT PN 30893

***FUSED ADAPTER

TO S2

SETUPS 15 & 16

ONLY

BLOWER

10A

TEST MODE OFF

DON’T ADD 1 HS PUMP W/HTR

DON’T ADD 2 HS PUMPS W/HTR

DON’T ADD 4 HS PUMPS W/HTR

SPECIAL AMPERAGE RULE A

STORE SETTINGS*

1 MIN HTR COOLDOWN (ELEC)

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

230V 3þ

3x16A

TEST MODE ON

ADD 1 HS PUMP WITH HEAT

ADD 2 HS PUMPS WITH HEAT

ADD 4 HS PUMPS WITH HEAT

SPECIAL AMPERAGE RULE B

MEMORY RESET*

5 MIN HTR COOLDOWN (GAS)

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

*SWITCH #

6

SHOULD BE SET TO OFF UPON FINAL INSTALLATION.

230V 1þ

1x32A

A2

A5

OFF

Advertising