TrackVIEW 100 System
The TrackVIEW 100 System uses the EVI-D70 with a wide-angle lens for the reference camera and an EVI-
D100 camera for the Tracking Camera. The EVI-D100 has a 10X optical zoom lens and will work well for small
room environments. Both cameras use the EZCamera cabling shoe and are powered from the TrackVIEW
controller. The EVI-D100 is to be mounted on the top shelf where the slot in the mount can accommodate the
¼”-20 mounting threads of the EVI-D100 or the EVI-D70.

















TrackVIEW HD-1 System
The TrackVIEW HD1 System uses the EVI-D70 with a wide-angle lens for the reference camera and the EVI-
HD1 camera for the Tracking Camera. The EVI-HD1 has a 12X optical zoom lens and will work well for any
environment that demands the quality of a HD imaging device. Both cameras use the EZCamera cabling shoe
and only the Reference EVI-D70 is powered from the TrackVIEW controller. The EVI-HD1 must use the Quick-
Connect PRO, EZIM and the supplied PowerRite power supply as the HD1 camera draws a significant amount
of power when panning and tilting.


















Figure 7:
Cameras and mount for the TrackVIEW 100 are pictured below; EVI-D70 (left), the EVI-D100 in platinum gray only
(center) and the dual thin line wall mount (right) fits on a standard 2-gang wall box or mounts with wall anchors.

Note: Use only the ¼”-20 camera mounting screws provided, using longer camera mounting screws will damage the camera an void the warranty.

Figure 8:
Cameras and mount for the TrackVIEW HD1 are pictured below; EVI-D70 (left), the EVI-HD1 with mounts.