GENERAL CONFIGURATIONS

The first screen shows some general parameters of configuration for the FieldLogger:

• Tag (name) to be given to the equipment (maximum of 16 characters).
• When using a HMI with the FieldLogger, please indicate the level of access that the operator will get through the

HMI:

o

No HMI access: Prevents the use of the HMI, because no parameter can be viewed by it in this
FieldLogger.

o

Parameters reading: HMI can be used only to view the channels and status of the FieldLogger, not
allowing any type of configuration.

o

HMI configuration and overall reading: HMI can have its own parameters configured, besides viewing
the channels and status of the FieldLogger.

o

Overall configuration and reading: HMI can be used to configure parameters (its own and some of
FieldLogger), in addition to viewing the channels and status of the FieldLogger.

• Enabling data download by using a USB flash drive: it enables or disables the data download by using a USB

flash drive. When enabled, it also indicates the priority in case of a USB flash drive without enough space to
download all demanded data: more recent data or older data. In addition, you can configure the number of days
(from the day of download, if the priority is the latest, or from the oldest data, if the priority is the oldest) that you
want to download. Because of the fact that we do not make a copy of all data from the equipment’s memory
(which, in the case of SD cards, can be a lot of data), this can accelerate download time significantly.