Prepare the foundation for mounting, Install and level the baseplate – Goulds Pumps 7200CB - IOM User Manual

Page 21

Advertising
background image

Installation

NOTICE:
You may need to sandblast the surfaces of a baseplate that come in contact with grout, and
then coat those surfaces with a primer that is grout-compatible. Make sure to remove all
equipment before sandblasting.

3. Make sure that all machined surfaces are free from burrs, rust, paint, or any other type of

contamination.
If necessary, use a honing stone to remove burrs.

Prepare the foundation for mounting

1. Chip the top of the foundation to a minimum of 1.0 in. (25.0 mm) in order to remove porous

or low-strength concrete.
If you use a pneumatic hammer, make sure that it does not contaminate the surface with oil
or other moisture.

NOTICE:
Do not chip the foundation using heavy tools such as jackhammers. This can damage the
structural integrity of the foundation.

2. Remove water or debris from the foundation bolt holes or sleeves.
3. If the baseplate uses sleeve-type bolts, then fill the sleeves with a non-binding, moldable

material. Seal the sleeves in order to prevent the grout from entering.

4. Coat the exposed portion of the anchor bolts with a non-bonding compound such as paste

wax in order to prevent the grout from adhering to the anchor bolts.
Do not use oils or liquid wax.

5. If recommended by the grout manufacturer, coat the foundation surface with a compatible

primer.

Install and level the baseplate

NOTICE:Illustrations are for reference only and may not depict the particular pump model.

WARNING:
Never operate any pumping system with a blocked suction and discharge. Operation, even for a brief
period under these conditions, can cause confined pumped fluid to overheat, which results in a violent
explosion. You must take all necessary measures to avoid this condition. If pump becomes plugged shut
down and unplug prior to restarting pump.

CAUTION:
Read this manual carefully before installing and using the product. Improper use of the product can
cause personal injury and damage to property, and may void the warranty.

Model 7200CB, API Type BB5 Barrel Multistage / ISO 13709 2nd Edition / API 610 11th Edition Installation, Operation, and

19

Maintenance Manual