Impeller, intermediate and discharge cover replacement

This table shows the criteria for replacment:

Impeller, intermediate and discharge cover

When to replace

parts
Impeller / Diffuser vanes

• When grooved deeper than 1/16 in. (1.6 mm),

or

• When worn evenly more than 1/32 in. (0.8 mm)

Vane edges

When you see cracks, pitting, or corrosion damage

Keyway and bores

When you see damage

Wear ring surfaces

When the clearance to the casing wear ring has
increased by 50% over the values in the Minimum
running clearances table

Impeller checks

• Check and clean the impeller bore diameter.

• Check the impeller balance. Rebalance the impeller if it exceeds the ISO G1.0 (4W/N)

criteria.