Goulds Pumps 7200CB - IOM User Manual

Page 59

Advertising
background image

Maintenance

16. Install cart to head (184) and tighten bolts (851K) with washers (853D).

17. Install stop plate (850J) and stop lever (850K) and tighten bolts (851L and 851M) and nut

(852B) with washers (853E and 853F).

18. Use the jackscrews (419) in order to loosen the head (184) from the casing (100). Push

bundle out of casing (100) until there is enough room to install the extension (850C). Install
extension (850C) and tighten bolts (851N).

19. Repeat line 18 until bundle is fully through the casing (100).

Model 7200CB, API Type BB5 Barrel Multistage / ISO 13709 2nd Edition / API 610 11th Edition Installation, Operation, and

57

Maintenance Manual

Advertising