C l e a n i n g a n d M a i n t e n a n c e

127.

E L E C T R I C M O D E L S

C l e a n i n g a n d M a i n t e n a n c e

D E C A L C I F I C A T I O N

ON BOILER EQUIPPED MODELS

u s i n g S c a l e F r e e ™ o r D i s t i l l e d W h i t e V i n e g a r

ScaleFree™

Descaling Compound is an acid-based descaler

combined with a proprietary chelating agent that is effective in dissolving and removing
carbonate, lime-scale and iron scale build-up caused by hard water. ScaleFree efficiently and
effectively removes lime-scale build-up from combi ovens.

ScaleFree™

is a non-hazardous, Biodegradable Citrus Based Powder that when mixed with

water becomes a powerful lime-scale remover.

It is VERY important to decalcify the oven, particularly in areas with extremely hard water.

PERFORM ONCE A MONTH in addition to the daily steam generator flush.

WITH THE OVEN AT ROOM TEMPERATURE

1.

Begin decalcification with the power
key in the OFF position.

2.

Open oven door. Wearing hand
protection, rotate the Steam Generator
Drain Cap

until water begins to flow

from the four holes in the cap. In
approximately 20 to 60 seconds, a
sufficient quantity of water will have
drained from the steam generator so
that the drain cap can be completely
removed.

3.

Let the water continue to drain until the
flow completely subsides. Replace the
Steam Generator Drain Cap

by

turning it clockwise until there is a
slight resistance. Close oven door.

4.

Using the batch mix instructions on the
label, mix up 1 gallon of ScaleFree™
solution at a time or one gallon of
distilled white vinegar for counter top
models and 3 gallons of distilled white
vinegar for floor standing models. Using
a funnel inserted into the Steam Relief
Valve

, slowly pour solution in to the Steam

Generator until full.

5.

Remove funnel from Steam Relief Valve

.

PRESS THE ON/OFF POWER KEY
TO THE ON
POSITION.

The unit will add water if needed.

PRESS THE STEAM PROGRAM KEY
The unit will begin to pre-heat.

DO NOT PRESS START.

(Continued on next page)

DURING DECALCIFICATION THE WATER FLOWING
FROM THE DRAIN CAP IS EXTREMELY HOT! USE
HAND PROTECTION WHEN TOUCHING THE STEAM
G E N E R AT O R D R A I N C A P. D O N O T T O U C H T H E
WATER FLOWING OUT OF THE STEAM GENERATOR
DRAIN CAP OR STEAM GENERATOR DRAIN.

S

T

A

N

D

A

R

D

C

O

N

T

R

O

L

D

E

L

U

X

E

C

O

N

T

R

O

L

STANDARD CONTROL

DELUXE CONTROL

STEAM RELIEF VALVE

STEAM
BYPASS PORT

STEAM EXIT
PORT

OVEN LIGHT

FAN

FAN GUARD
COVER PLATE

STEAM
GENERATOR
DRAIN CAP

OVEN DRAIN