Do not cook in any program mode with scalefree, Or vinegar in the steam generator system – Alto-Shaam COMBITHERM 1020 User Manual

Page 133

Advertising
background image

C l e a n i n g a n d M a i n t e n a n c e

130.

ALLOW THE UNIT TO PREHEAT FOR 30 MINUTES.

After a period of 30 minutes —

TURN THE SELECTION KNOB TO THE OFF POSITION.

6.

Open the oven door.

USING HAND PROTECTION

, rotate the Steam Generator Drain Cap

until

water begins to flow from the four holes in the cap. In approximately 20 to 60 seconds, a sufficient
quantity of water will have drained from the steam generator so that the drain cap can be completely
removed. Let the water continue to drain until the flow completely subsides.

7.

Loosen the thumb screw(s) and swing Fan Guard Cover Plate

toward the back of the oven. Using the

hand-held hose, direct a stream of water directly into the Steam Generator Drain

and Steam Exit Port

several times. Close the swing-out Cover Plate

. Lock the cover into place and tighten thumb

screw(s). Close the oven door.

TURN THE SELECTION KNOB TO THE STEAM POSITION.

A new supply of fresh water will begin to flush the steam generator.

ALLOW THE WATER TO RUN FOR

2 MINUTES

OF OPERATION IN THE STEAM MODE,

to continue to flush out all remaining solution.

TURN THE SELECTION KNOB TO THE OFF POSITION.

8.

Open oven door.

USING HAND PROTECTION

, replace the Steam Generator Drain Cap

by

turning it clockwise until there is a slight resistance. Close oven door.

TURN THE SELECTION KNOB TO THE STEAM POSITION.

The unit will start to fill.

ALLOW UNIT TO RUN FOR 20 MINUTES IN THE STEAM MODE.

TURN THE SELECTION KNOB TO THE OFF POSITION.

9.

Open the oven door.

USING HAND PROTECTION

, rotate the Steam Generator Drain Cap

until

water begins to flow from the four holes in the cap. In approximately 20 to 60 seconds, a sufficient
quantity of water will have drained from the steam generator so that the drain cap can be completely
removed. Let the water continue to drain until the flow completely subsides. Replace the Steam
Generator Drain Cap

by turning it clockwise until there is a slight resistance.

At the end of the production day, leave the door slightly ajar.

THE UNIT IS NOW READY TO BE USED.

DO NOT

COOK IN ANY PROGRAM MODE WITH

ScaleFree

OR VINEGAR IN THE STEAM GENERATOR SYSTEM.

C l e a n i n g a n d M a i n t e n a n c e

E L E C T R I C M O D E L S