1. Digital display

2. On/Off

3. Hold key

4. Shift key (%)

5. Calibration key

6. Signal / backlight key

7. Battery compartment

8. Horizontal vial

9. Vertical vial

Prior to use

Check Battery

Before every operation the battery should be checked. If the

digital display is flashing or showing a battery symbol then the

battery life is low and should be replaced prior to any

measurements being taken. This product requires 1x9v battery.

Product Familiarisation

Digital Level

Operating Instructions

Display

The display automatically rotates depending on its orientation.

See image below (Fig 1).

Fig 1

Control Panel

Automatic power shutdown

This unit will shut down automatically if it has not been in use

for more than 3 minutes.

Hold Key

In some instances it may not be possible to clearly read the

display screen. By pressing the hold key (3) it is possible to

retain a reading on the display screen and remove the level

from the measuring surface.

The saved measurement will be indicated by a series of

flashing arrows either side of the measurement.

NOte: while the unit is set in the hold position no other

measurements can be taken.

To reset the level press the hold key (3) again.

Variations

To get an accurate reading out of the digital level it always

must be placed on the milled face.

NOte: If the level is not placed on its milled face it will not

give an accurate or correct reading.

Fig 2.

Signal / Backlight

The signal / backlight key (6) has 2 functions.

Press the key for less than five seconds and the level is set

to emit a beeping noise when making a measurement.

Press the signal / backlight key (6) again to reset the level

back to silent operation.

If the signal / backlight key (6) is pressed for longer than 5

seconds then the display screen backlight will come on.

Pressing the key again for more than 5 seconds turns the

backlight off.

Maintenance

Battery

The battery in this unit will need replacing if the display is as

shown below.

Fig.3

Storage

This spirit level should not be exposed to temperatures

below 0˚C. It should be stored in a dry place and protected

against vibrations. When not using this product for a longer

period of time, it is recommended to take the battery out of

the product.

1

2

3

4

5

6

7

8

9

Calibration

For accurate and reliable readings, prior to use the level should

be properly calibrated. This process also should be done if the

level has been subject to a strong vibration or impact. Follow

the process stated below to calibrate the level.

1. First make sure the level is switched on. To do so press the

on/off button (2).

2. Then press and hold the calibration button (5) for up to 3

seconds, the display will then flash "Cal 1".

3. The display will flash the gradient that the level finds it self

on. Then place the milled face of the level down onto a

known level surface.

4. Press and hold the calibration button for up to 3 seconds and

the display will flash "Cal 2".

5. after this stage calibration is complete and it should find 0˚

on the known level surface which it was calibrated on.

NOte: When the level is indicating 0˚ after calibrating it will

give of an audible signal.

SPeCIFICAtION

Overall length 600mm

Precision 0.5mm/1m

Measuring range of digital display 4x90˚

Working temperature range 0˚C - 40˚C

Display resolution +/-0.1˚

Display precision +/-0.3˚

Battery 9 volt