Individual unit – Festo Стандартные цилиндры DNC-V с распределителем User Manual

Page 17

Advertising
background image

Pneumatic linear cylinder

Festo 0506a English

17

Individual unit

Warning

1. Make sure that:

Ĉ nobody can place his/her hand in the

positioning range of the moveable
mass

ć there are no objects in the positioning

range.

2. Close both upstream one−way flow control valves:

ć at first completely,
ć then loosen approximately one turn.

3. Close the adjusting screws for the end position cushioning

ć at first completely (with DNCB−.. close completely);
ć then loosen again approximately one turn (with DNCB−...

¼ turn).

4. Note that adjustable end position cushionings may have no effect if used in

conjunction with fitted quick exhaust valves.

This depends on the flow ratio of the exhaust air.

5. Exhaust the cylinder slowly on one side.

Otherwise excessive loadings will occur during the first move, if the piston
moves too quickly into an end position.
For slow start−up pressurization use safety start−up valve type HEL−...Ă.

6. Start a test run.

7. During a test run check whether the following settings on the cylinder need to

be modified:

ć the end position cushioning
ć the speed of the moveable mass.

With masses which project longitudinally
over the bearing/end cover:

In this case the following screws may only
be turned when the cylinder is at a stand:

ć the adjusting screws for the one−way

flow control valves

ć the adjusting screws for the end posiĆ

tion cushioning.

Fig. 8

Fig. 9