11 communication parameters, Communication parameters, Table 5: communication parameters – Kramer Electronics VP-8x4AK User Manual

Page 40

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Communication Parameters

36

11 Communication Parameters

Table 5

lists the communication parameters as used in Kramer Electronics

products.

Table 5: Communication Parameters

EDID

EDID data is passed between Output 1 and Input 1

RS-232

Protocol 2000

Protocol 3000 (Default)

Baud Rate:

9600

Baud Rate:

115,200

Data Bits:

8

Data Bits:

8

Stop Bits:

1

Stop Bits:

1

Parity:

None

Parity:

None

Command Format:

HEX

Command Format:

ASCII

Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1): #AV 1>1<CR>

Switching Protocol

P2000 -> P3000

P3000 -> P2000

Command:

0x38, 0x80, 0x83, 0x81

Command:

#P2000<CR>

Front Panel:

Press and hold Output 1 and

Output 3 simultaneously

Front Panel:

Press and hold Output 1 and

Output 2 simultaneously

Ethernet

Default Settings

Reset Settings

IP Address: 192.168.1.39

Power cycle the unit while holding in the Factory Reset button, located on

the rear panel of the unit.

TCP Port #: 5000

UDP Port #: 50000