Basic fasnseal flex liner installation, Tee installation – DuraVent FasNSeal Single-Wall User Manual

Page 14

Advertising
background image

14

7. Repeat steps 3 through 5 for other end.

8. Before installation, let cure for a minimum

of 24 hours or follow the cure time called out

by the silicone manufacturer.

BASIC FASNSEAL FLEx LINER

INSTALLATION

1. Determine the required location and

opening in the masonry chimney. For a basic

FasNSeal Flex installation the opening must be

large enough for the mortar sleeve and Male

Flex Adapter to easily pass through. If a Tee

application is necessary, a larger hole may be

required. (See Tee Installation Section)

2. Make sure the union of the Male Flex

Adapter and the FasNSeal Flex is supported at

the bottom of the chimney.

3. The flex liner must be installed from the top

of the masonry chimney. To prevent damage,

one person should feed the liner through the

chimney and another person should pull the

liner from the bottom. To ease the installation,

you can attach a rope to the FasNSeal Flex

liner above the Male Flex Adapter. Doing this

will reduce the chance of breaking the seal

between the FasNSeal Flex and the Male

Flex Adapter.

4. The FasNSeal Flex must stay within the

masonry chimney; however the Elbow or

other FasNSeal components will extend

beyond the masonry chimney. (Figure 14)

5. It is strongly recommended to use either

a Universal Condensate Drain or Tee with

Condensate Fitting right off the Male Adapter

coming out of the chimney.

TEE INSTALLATION

Figure 14

Figure 12

Figure 13

ADD SILICONE IN

CHANNEL

INSERT LINER
UNTIL BOTTOMED
OUT IN ADAPTER
(MIN 1.5" / MAx 2")

CONDENSATE

DRAIN

ELBOW/TEE

FEMALE
ADAPTER

FLEx
SECTION

MALE
ADAPTER

VENT
SECTION

Advertising