FASNSEAL VENT KIT

INSTALLATION INSTRUCTIONS

1. Examine all components for possible

shipping damage prior to installation

2. Determine the location and cut an opening

for the wall thimble (refer to Figure 18).

• Position Part A into the opening so that

angled hood is located on the outside of the

structure.

• Apply a bead of silicone between the

structure and mounting plate before nailing

or screwing Part A to the outside surface of

the building.

• From the inside, slide the sleeve of Part B

onto the sleeve of Part A until the plate of

Part B is flush against the inside wall. Fasten

with screws or nails.

3. Slide the 12-inch long appliance adapter or

12-inch standard vent length over one end of

the elbow. Insert the other end of the elbow

into the wall thimble.

• For kit FSWMK4 pull the appliance adapter

over the vent collar and secure it with the

built-in locking band.

For kit FSWMKB3 insert the male end of the

standard vent length into appliance collar

and secure it with the built-in locking band.

• Adjust the elbow to achieve the desired

pitch.

• Fasten the locking band located on the wall

thimble using 1/4” drive rachet with 5/16

socket.

When installing the elbow, it is important

to make sure that each end is inserted past

the silicone gasket. To ensure the elbow fully

engages each gasket, at least two inches of

the elbow must be inserted. This minimum

requirement is met as soon as the double

lines etched into the ends of the elbow are

covered (refer to Figure 19).

If you are unable to install the elbow past the

indicated lines, additional vent lengths must

be installed. Prior to initial start up, check the

PART A

OUTSIDE
BUILDING
SURFACE

INSIDE
BUILDING
SURFACE

PART B

2" x 6" STUD
(COMBUSTIBLES)

4.5" +/- 9.0"

1.0"

1.5"

TO APPLIANCE

Figure 18

INSERT THE ELBOW UNTIL THE FLARED

END OF THE FEMALE PROFILE COVERS

BOTH ETCHED LINES

CORRECT

INCORRECT

TIGHTEN CLAMP
UNTIL SNUG (DO NOT
OVERTIGHTEN)

Figure 19

Advertising