Vent size and length, Adjustable vent length, Fsavl – DuraVent FasNSeal Single-Wall User Manual

Page 6: Fsvl figure 1

Advertising
background image

6

VENT SIzE AND LENgTH

Refer to the appliance manufacturer’s

installation instructions for proper size and

vent configuration. Follow any horizontal/

vertical length and height limitations,

minimum clearances (air space) to

combustibles, or specifications for the use of

Elbows, Tees, or Drain Tees.

Although our Adjustable Vent Length and

Wall Thimble are designed to eliminate

cutting, there may be occasions when you

must field cut a vent length.

FIELD CUTTINg: When necessary, cut

the male end only and keep in mind that

a minimum of 2” vent length is needed

to obtain a seal on the female end. Make

a straight cut to ensure the gasket is

completely covered. Sand all burrs off

to avoid damaging the gasket during

installation. When these procedures are

followed, FasNSeal® may safely be cut in the

field.

ADJUSTABLE VENT LENgTH

The FasNSeal Adjustable Vent Length (FSAVL)

is available in all diameters and allows

the installer to easily adjust the vertical or

horizontal length of a vent system. Cutting, or

piecing together several vent lengths can be

avoided.

The FasNSeal Wall Thimble (FSWT) already

incorporates the FSAVL. In most system

layouts, this provides enough adjustability for

the horizontal vent run.

Use the FSAVL vertically for easy adjustment

of the required minimum 1/4” per foot pitch.

Technical details about the stand alone FSAVL

(see Figure 1): The overall length of all FSAVL

Adjustable Vent Length is 18” (1).

The female end (2) measures 2”, leaving 12” to

telescope into a standard vent length.

The FSAVL must penetrate no less than 4” into

a standard vent length (3) to assure a good

seal and structural stability. This leaves up to

12” in true axial adjustability (4).

12.00”

ADjUSTABILITy

(4)

FSAVL

2.00”

(2)

18.00”

OVERALL

LENGTH (1)

4.00”

PENETRATION (3)

FSVL

Figure 1

Advertising